top of page

DRILLING PILE TESTING

Pile Testing

Inspections of our bored piles are carried out according to the following standards:

LVS EN 1997-1; ISO/DIS 22477-1; ГOST 5686-2012

TILTS SIA offers to test bored piles with the following methods:

  • Static testing

  • Integrity testing (with ultrasound) - PIT

  • Dynamic testing

  • Crosshole Sonic Logging (CSL) testing

STATIC TESTING OF DRILL PILES

Static test – determination of the bearing capacity of the pile depending on the technical data of the pile and soil conditions. Static tests of piles can be carried out:

Pile Testing

A
With reinforced concrete blocks

Pile Testing
Pile Testing

B
With additionally constructed anchor piles

Pile Testing

DRILL PILE INTEGRITY TESTING (USING ULTRASOUND)

Pile integrity test - PIT - this method makes it possible to detect individual pile defects (ruptures, expansions, narrowing, depressions caused by soil exposure, pits) and to determine the length of the piles.

46.PNG

Ultrasonic pile inspection

as.PNG
Pile Testing
Pile Testing

OK

Picture4.png

FAMOUS

DYNAMIC TESTING OF DRILL PILES

Pile Testing

Dynamic Test (DLT)

The dynamic test (DLT) allows to determine the bearing capacity of the foundation and side surfaces of the piles, to evaluate the integrity of the piles, as well as their sinking. Measurements are analyzed in real time using special software. One of the test results is a static test simulation in the form of a calculated load test curve.

 

The tests are performed with a specially made free fall hammer, which has been owned by TILTS SIA since 2021

CROSSHOLE SONIC LOGGING (CSL) TESTING OF DRILL PILE

Here is a very accurate method for determining structural integrity and concrete uniformity in diaphragm walls in bored piles:
• Widely used for more than 30 years.
• Practical and economical for deep foundation integrity testing.

qe5r.PNG

Crosshole Sonic Logging (CSL)

2.PNG

The standard size of bored piles is 1000 - 1400 mm

Method

Crosshole sonic logging (CSL) is a method to determine the structural integrity of drilled shafts and other concrete piles. The CSL method is considered to be more accurate than sonic echo testing in the determination of structural soundness of concrete within the drilled shaft inside of the rebar cage. CSL) is one of the most accurate pile integrity tests to determine the integrity of deep foundation elements. CSL sends ultrasonic pulses through the concrete from one probe to another probe present in a pile and detects the structural integrity based on the received waves.

Advantages

  • Quick and safe – CSL tests performed in less than 5 minutes

  • Can perform tests for above and below waterline structures

  • Identify and locate the presence of multiple defects

  • CT can deliver high-resolution images with unsurpassed accuracy and interpretation simplicity

  • Perform QA regarding the presence of poor quality concrete, voids, honeycombing and soil intrusion

  • Identify the size, shape, severity, nature and location of anomalies

CONTACTS

lo.PNG

SIA TILTS

Registration number: 50103005351

Address: Spilves iela 18, Riga, LV 1055, Latvia

Bank: OP Corporate Bank plc Latvia

SWIFT code: OKOYLV2X

Bank account number: LV82OKOY0005100035077

To receive a price offer for your individual project, please contact our specialists by phone or e-mail.

bottom of page